| PROBLEM: |
Oscillator motor runs, but head does not move side to side. |
| SOLUTIONS: |
- Check to be sure Control Levers are in a position other than 1,6. Reposition, if necessary. (all models except 1050 and 2050)
- A gear post, lever, or the Control Lever Adapter has broken. Replace. (all models except 1050 and 2050) See Owner’s Manual.
- Oscillator has not been assembled correctly. Be sure top pin of Pivot Guide is positioned correctly inside the hole at the bottom of the Oscillator Motor Cover and bottom pin of Pivot Guide is in the corresponding hole of the Ball Feed Upper Guide. (all models except 1050 and 2050) See Owner’s Manual.
|
| |
|
| PROBLEM: |
Oscillator operates, but oscillator control levers jump out of place while oscillator runs. |
| SOLUTIONS: |
- Control Levers are bent or cracked. Levers can sometimes be carefully bent back into shape when softened by heating. Otherwise, replace. (all models except 1050 and 2050) See Owner’s Manual.
|
| |
|
| PROBLEM: |
Oscillator operates, but motion is jerky and/or straining noises are heard. |
| SOLUTIONS: |
- Oscillator Motor Cover is pressing down on the Control Levers, restricting their movement. Remove cover and file or scrape away a little of the bottom edge of the cover that is directly above the levers. (all models except 1050 and 2050)
- Rough mold parting seams on the top and/or bottom of Oscillator Pivot Guide. Smooth seams with a file or sharp knife. (all models except 1050 and 2050)
|
| |
|
| PROBLEM: |
Robot does not deliver the ball all the way to either the left or right corner of the table when spin is set to straight topspin or backspin and control levers are set to positions 3 & 4. |
| SOLUTIONS: |
- See Owner’s Manual.
- Make sure fit of Control Lever Adapter to Pivot Guide is very tight. If loose, replace Control Lever Adapter. (all models except 1050 and 2050.)
- Be sure Clear Front Cover is properly snapped into place.1,2 (all models except 1050 and 2050)
- Examine plastic pins on top and bottom of Oscillator Pivot Guide. Pins should be straight and exactly perpendicular to the top and bottom surfaces. If either pin is crooked, replace Pivot Guide. (all models except 1050 and 2050).
|